SLT-16 Super Lightweight Wire/Cables
Product #: SPACE-16SR2S23
Super Lightweight Cables XLETFE 150°C/450 VConductors: Conductor shall be built per Whitmor/Wirenetics drawing SLT-1.Cabling: The required number of conductors, determined by cable designation, will be cabled with a left-hand lay. The lay length of the individual conductors shall be not less than 8 nore more than 16 times the outside major axis diameter of the unshielded, unjacketed cable.Shield: When a shielded construction is called for in the cable designation, either a closely woven round strand braid or a flat strand braid will be used over the conductors.Jacket: When a jacketed construction is called for in the cable designation, the wall thickness will be a nominal of .004" - .008" of either EFFE or irradiation crosslinked ETFE.
Specifications
| Max. Diameter | 0.173 in |
| Max. Weight | 25.64 lb/1000 ft. |
| Percentage of Shield Coverage | 85 % |
| Color Code | (-) White Base with Stripes |
| Color | 1st: White |
| 2nd: White/Blue | |
| 3rd: White/Orange | |
| 4th: White/Green | |
| 5th: White/Red | |
| 6th: White/Black | |
| 7th: White/Yellow | |
| 8th: White/Violet | |
| Conductor Type | Silver Plated Copper |
| # of Conductors | 2 |
| Shield Type | Silver Plated Copper, Round |
| Jacket Type | Extruded XLETFE (White) |